Pentair MYERS S33 Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 7
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
P. 6
23833A587 Bag #18812A108
P. 7
23833A587 Bag #18812A108
SYMPTOMS
Pump does not run or hum. X X X X X X
Pump runs but does not deliver water. X X X X X X
Pump runs and pumps out sump but does not stop. X
Pump runs but delivers only small amount of water. X X X X
Fuse blows or circuit breaker trips when pump starts. X X X X
Motor runs for short time then stops. Then after short
period starts again. Indicates tripping overload X X X
caused by symptom shown.
For any other symptoms call Myers Service Dealer. Check tether length of switch per directions.
Service
Chart
SOLUTIONS
Line circuit breaker may be off, or fuse, if used, may be blown or loose.
Water level in sump may be too low. Run in more water. Turn-on level is 12 to
13 inches above sump bottom.
Pump cord plug may not be making contact in receptacle.
If pump is using the series cord plug, the two plugs may not be plugged
tight together.
Float may be stuck. Be sure oat operates freely in basin.
If all symptoms check OK, motor winding may be open. Take to service center
for check.
Check valve may be installed backward. Arrow on valve points in direction
of ow.
Discharge shut-off valve, if used, may be closed.
Pump may be air locked. Start and stop several times by plugging and
unplugging cord. Check vent hole in pump case for plugging.
Pump head may be too high. Pump cannot deliver water over 18 ft. vertical.
Horizontal distance does not affect pumping, except loss due to friction.
Inlet holes in pump base may be clogged. Remove pump and clean
out openings.
Impeller or volute openings may be plugged or partially plugged. Remove
pump and clean per maintenance instructions.
Float is stuck in up position. Be sure oat operates freely in basin.
Fuse size or circuit breaker is too small. Must be 15 amps.
Defective motor stator; return to Myers service center.
Seitenansicht 5
1 2 3 4 5 6 7

Kommentare zu diesen Handbüchern

Keine Kommentare